Mapping out the roof assembly for a new house in climate zone 6b steve mackay has settled on long i joists insulated with a mix of closed cell spray polyurethane foam and blown in fiberglass.
Vented roof assembly.
Control construction moisture content with tenting or temporary roofing when necessary.
A vented roof system can only work properly and remove the moisture from a roof assembly if.
Shingles that are installed on unvented roof assemblies operate at slightly higher temperatures roughly 2 f to 3 f warmer than shingles on vented assemblies.
They are designed without ventilation openings and the attic is conditioned like the rest of the living space.
To be placed on the underside and in direct contact with the roof sheathing.
The total insulation r value for the assembly will be an r 39 r 20 r 19.
This can reduce their service life by roughly 10.
Because the drying capacity of unvented roof assemblies is inherently lower than vented ones it is especially critical to control built in moisture during construction.
Unvented roof assemblies are becoming an increasingly common construction alternative to traditional vented roofs.
These assemblies are created by eliminating ventilation openings and moving the thermal moisture and air control boundaries to the plane of the roof deck.
Air permeable insulation such as fiberglass batts dense packed cellulose or blown in fiberglass can t be used alone for an unvented assembly since these types of insulation can allow moist indoor air to reach the cold roof sheathing leading to condensation or moisture accumulation.
Some manufacturers don t warranty or offer only a limited warranty when their products are used over an unvented roof assembly.
Unvented roof assemblies such as conditioned attics and unvented cathedral ceilings are becoming common in north american construction.
However designers of compact roof assemblies must consider vapor permeance and arrangement of the roofing materials to produce acceptable hygrothermal performance and low.
Moisture content in roof structure must be less than 18 prior to covering.
He doesn t plan on venting the roof and he wants to be certain his design will be problem free.
Unvented roof systems where the insulation and air barrier are applied directly to the underside of the roof deck are common in applications where designers are seeking cost effective and energy efficient roof assemblies.
Sc historically typical construction of homes in canada and the us have vented attics between the ceiling of the interior space and the roof.
An unvented assembly can perform well but it s important to get the details right to avoid sheathing rot.
Un ven ted roof ˌənˈven t əd ro of an unvented roof assembly is constructed without any ventilation and is fully sealed on all sides and filled with insulation.