In this case you can learn a lot from foam tech s article vented vs.
Vented vs non vented roof.
Because the drying capacity of unvented roof assemblies is inherently lower than vented ones it is especially critical to control built in moisture during construction.
It has the ability to work with vaulted ceilings and you only need one of them to get the job done for ventilation as compared to multiple box vents.
There are traditionally four main reasons for venting a roof.
Moisture content in roof structure must be less than 18 prior to covering.
25 mm of ccspf against the underside of the roof deck to prevent air leakage through the roof assembly and to prevent moist indoor.
Joseph lstiburek from building science corporation.
Control airflow install at least 1 in.
Enhancing roofing material life span by reducing sheathing temperature.
Basically the term cold roof refers to a traditional roof or vented roof while hot roof refers to a roof that is not ventilated and which has foam insulation attached directly to the roof sheathing.
Removing moisture from roof cavities structural members sheathing and insulation.
Non vented soffits are the same panels but they are missing the holes or screens that are found often in plywood soffit that allow air into the roof.
One may ask that given the value of the air flow in the attic why would anyone choose non vented.
It is the more expensive vs.
The choice of the venting approach is up to the designer.
Unvented roofs which provides a detailed explanation of each.
A box roof vent but it s still non mechanical so you will not need to spend money on electrical issues or failures in the system.
Minimum 1 4 in.
Additionally during high wind events vented soffit collapse leads to building pressurization and window blowout and roof loss due to increased uplift.
Unvented roofs vented roof.
In high wind regions particularly in coastal areas wind driven rain is a problem with vented roof assemblies.
Control of ice dams moisture accumulation and heat gain can be successfully addressed by both vented and unvented attic or roof design.
Or 6 mm vented airspace should be installed between the roofing and the underlayment.
Control construction moisture content with tenting or temporary roofing when necessary.
Learn the difference between vented soffit and non vented soffit.
If wood shingles or shakes are used a layer of drainage mat e g.
Controlling ice damming by keeping the roof cold.
However the designs need to be climate sensitive.
Both vented and unvented attic roof designs can be used in all hygro thermal regions.